ABB Welcome Manual de Serviço Página 40

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 56
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 39
ABB
-Welcome M
Operation
| — 40 —
3. Modify the "door open code"
#* system password # =>
3# => Enter new door open code (6-8 bits) # => Enter the code again #
4. Setting the voice message
If the audio module with the speech synthesis function (M251024A-.) is assembled,
the local language can be set.
#* system password # =>
4# => Press or to choose the language => #
5. Enable/disable the access control function
Enable access control function:
#* system password # =>
5# => 1 #
Disable access control function:
#* system password # =>
5# => 2 #
*Reset the system password of keypad module:
It is possible to reset the system password to factory-setting if you have forgotten it.
The restoration of default factory settings does not delete the rest of the
information programmed on the system, such as user names and other settings.
1. Disconnect the power supply.
2. Reconnect the power
3. Hold the “program buttonfor 5s within 30s.
4. A “di” will be sounded and the system password will be reset to the default
(345678).